{"id":5992,"date":"2017-10-26T18:48:31","date_gmt":"2017-10-26T09:48:31","guid":{"rendered":"https:\/\/www.jpu.or.jp\/eng\/?page_id=5992"},"modified":"2023-09-25T17:39:01","modified_gmt":"2023-09-25T08:39:01","slug":"force-sensor","status":"publish","type":"page","link":"https:\/\/www.jpu.or.jp\/eng\/force-sensor\/","title":{"rendered":"Force sensor"},"content":{"rendered":"<table style=\"width: 100%;\">\n<tbody>\n<tr style=\"height: 22px;\">\n<td style=\"background-color: #d0d9f2; width: 13.9286%; text-align: center; height: 22px;\"><strong>Appearance<\/strong><\/td>\n<td style=\"background-color: #d0d9f2; width: 71.4286%; text-align: center; height: 22px;\"><strong>Products Name<\/strong><\/td>\n<td style=\"background-color: #d0d9f2; width: 13.4524%; text-align: center; height: 22px;\"><strong>Maker<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 39px;\">\n<td style=\"text-align: center; width: 13.9286%; height: 39px;\"><a href=\"https:\/\/www.jpu.or.jp\/eng\/micro-force-sensor\/\"><img loading=\"lazy\" class=\"alignnone wp-image-769 size-full\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/02\/fs1-1.jpg\" alt=\"\" width=\"250\" height=\"167\" \/><\/a><\/td>\n<td style=\"width: 71.4286%; height: 39px; text-align: left;\"><span style=\"font-size: 12pt;\"><a href=\"https:\/\/www.jpu.or.jp\/eng\/micro-force-sensor\/\"><strong>Micro force sensor<\/strong><\/a><\/span><\/p>\n<p>Micro force in \u03bcN (mgf) can be detected and measured. The light and compact body can be easily handled and assembled into a device.<\/p>\n<\/td>\n<td style=\"width: 13.4524%; height: 39px; text-align: center;\">THK Precision Co., Ltd.<\/td>\n<\/tr>\n<tr style=\"height: 95px;\">\n<td style=\"text-align: center; width: 13.9286%; height: 95px;\">\u00a0<a href=\"https:\/\/www.jpu.or.jp\/eng\/high-load-sensor\/\"><img loading=\"lazy\" class=\"alignnone wp-image-772 size-full\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/02\/fs2-1.jpg\" alt=\"\" width=\"250\" height=\"167\" \/><\/a><\/td>\n<td style=\"width: 71.4286%; height: 39px; text-align: left;\"><span style=\"font-size: 12pt;\"><a href=\"https:\/\/www.jpu.or.jp\/eng\/high-load-sensor\/\"><strong>High load sensor<\/strong><\/a><\/span><\/p>\n<p>100N load can be detected with high resolution. Optimal for force measurement of precision machining and precision press, etc.<\/p>\n<\/td>\n<td style=\"width: 13.4524%; height: 39px; text-align: center;\"><span style=\"font-family: Meiryo, \u30e1\u30a4\u30ea\u30aa, sans-serif;\">THK Precision Co., Ltd.<\/span><\/td>\n<\/tr>\n<tr style=\"height: 12px;\">\n<td style=\"text-align: center; width: 13.9286%; height: 12px;\"><a href=\"https:\/\/www.jpu.or.jp\/eng\/force-sensor-amp\/\"><img loading=\"lazy\" class=\"alignnone wp-image-775 size-full\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/02\/fs3-1.jpg\" alt=\"\" width=\"158\" height=\"167\" \/><\/a><\/td>\n<td style=\"width: 71.4286%; height: 39px; text-align: left;\"><span style=\"font-size: 12pt;\"><a href=\"https:\/\/www.jpu.or.jp\/eng\/force-sensor-amp\/\"><strong>Sensor amplifier<\/strong><\/a><\/span><\/p>\n<p>Common low noise amplifier for &#8220;Micro Force Sensor&#8221; and &#8220;High Load Sensor&#8221;.<\/p>\n<\/td>\n<td style=\"width: 13.4524%; height: 39px; vertical-align: middle; text-align: center;\"><span style=\"font-family: Meiryo, \u30e1\u30a4\u30ea\u30aa, sans-serif;\">THK Precision Co., Ltd.\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"background-color: #0404b4;\">\n<tbody>\n<tr style=\"height: 21px;\">\n<td style=\"height: 21px;\"><span style=\"font-family: Meiryo, \u30e1\u30a4\u30ea\u30aa, sans-serif; font-size: 14pt; color: #ffffff;\"><strong>Technical Information<\/strong><\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><span style=\"font-size: 14pt; color: #0000ff;\"><strong>Mechanistic principle<br \/>\n<\/strong><\/span>Displacement under a micro force on the sensing parts supported by an elastic hinge guide is measured by a high-resolution capacitive sensor.<\/p>\n<p><img loading=\"lazy\" class=\"size-full wp-image-6000 alignleft\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/10\/force_tech_image2_en.gif\" alt=\"\" width=\"312\" height=\"172\" \/><\/p>\n<p style=\"text-align: left;\">\n<p style=\"text-align: left;\">\n<p style=\"text-align: left;\">\n<p style=\"text-align: left;\"><span style=\"font-size: 14pt; color: #0000ff;\"><strong>Measurement date examplesiple<\/strong><\/span><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 263px;\"><img loading=\"lazy\" class=\"alignleft wp-image-5997 size-medium\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/10\/force_tech_image_en-300x245.gif\" alt=\"\" width=\"300\" height=\"245\" \/><\/td>\n<td style=\"text-align: left; width: 556px;\"><strong>SENSITIVITY<\/strong><\/p>\n<p>Multiple inspection weights with prescribed loads are placed on the force sensor to measure the output voltage relative to the weight and obtain the sensitivity coefficient(V\/N).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 263px;\"><img loading=\"lazy\" class=\"alignleft wp-image-5998 size-medium\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/10\/force_tech_image_en_06-300x230.gif\" alt=\"\" width=\"300\" height=\"230\" \/><\/td>\n<td style=\"text-align: left; width: 556px;\">\u00a0<strong>LINEARITY<\/strong><\/p>\n<p>Sensitivity line of the sensor output and measured load difference are expressed in percent of the sensor voltage for the rated load.<br \/>\nThe largest absolute values of positive and negative errors are taken and represented as \u201c\u00b1\uff0a\uff0a% or below \u201c.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 263px;\"><img loading=\"lazy\" class=\"alignleft wp-image-5999 size-medium\" src=\"https:\/\/www.jpu.or.jp\/eng\/wp-content\/uploads\/2017\/10\/force_tech_image_en_08-300x203.gif\" alt=\"\" width=\"300\" height=\"203\" \/><\/td>\n<td style=\"text-align: left; width: 556px;\"><strong>RESOLUTION<\/strong><\/p>\n<p>Load or displacement equivalent to the resolution is given to check that the steps of the sensor output voltage is recognizable.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\">\n<p style=\"text-align: left;\">\n<p style=\"text-align: left;\">\n","protected":false},"excerpt":{"rendered":"Appearance Products Name Maker Micro force sensor Micro force in \u03bcN (mgf) can be detected and measured. The li &#8230;","protected":false},"author":5,"featured_media":1461,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-onecolumn.php","meta":[],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/pages\/5992"}],"collection":[{"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/comments?post=5992"}],"version-history":[{"count":24,"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/pages\/5992\/revisions"}],"predecessor-version":[{"id":7798,"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/pages\/5992\/revisions\/7798"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/media\/1461"}],"wp:attachment":[{"href":"https:\/\/www.jpu.or.jp\/eng\/wp-json\/wp\/v2\/media?parent=5992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}