It measures by reflection method.
It measures the exposure time, shutter speed etc of the focal plane shutter at 3 points.
It can measure the digital camera of finished product.
It measures exactly up to 1/8000 seconds.
Automatic sensitivity adjustment.
Seven times measurements in a second.
Start time lag of left, center and right.
With a PC, it can be set up and measured.

Specification

To be measured Focal-plane shutter unit, shutter unit, finished camera
Measurement method Reflection
φ0.1mm laser spot light is irradiated to the front of a CCD element (filter section).
Catoptric light is detected when a shutter of source container opens.
Push the shutter release before measurement , it is caribrated automatically
Display 5ch(7segment)
Measurement range 0.001ms-16s
Measurement time 0.001ms-16.0s
Light source Lazer spot light λ=780nm (Power:1mW(classII))
Measurement accuracy ±5μs
External control RS-232C
Power supply AC100V-240V, 50/60Hz
Power consumption About 15VA
Dimensions 230(W) 480(H) 462(D)mm
Weight 10.0Kg
Measurement item

Displayed in tables and images